Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 34.890
Filter
2.
PLoS One ; 19(5): e0296696, 2024.
Article in English | MEDLINE | ID: mdl-38722966

ABSTRACT

BACKGROUND: With recent advances in magnetic resonance imaging (MRI) technology, the practical role of lung MRI is expanding despite the inherent challenges of the thorax. The purpose of our study was to evaluate the current status of the concurrent dephasing and excitation (CODE) ultrashort echo-time sequence and the T1-weighted volumetric interpolated breath-hold examination (VIBE) sequence in the evaluation of thoracic disease by comparing it with the gold standard computed tomography (CT). METHODS: Twenty-four patients with lung cancer and mediastinal masses underwent both CT and MRI including T1-weighted VIBE and CODE. For CODE images, data were acquired in free breathing and end-expiratory images were reconstructed using retrospective respiratory gating. All images were evaluated through qualitative and quantitative approaches regarding various anatomical structures and lesions (nodule, mediastinal mass, emphysema, reticulation, honeycombing, bronchiectasis, pleural plaque and lymphadenopathy) inside the thorax in terms of diagnostic performance in making specific decisions. RESULTS: Depiction of the lung parenchyma, mediastinal and pleural lesion was not significant different among the three modalities (p > 0.05). Intra-tumoral and peritumoral features of lung nodules were not significant different in the CT, VIBE or CODE images (p > 0.05). However, VIBE and CODE had significantly lower image quality and poorer depiction of airway, great vessels, and emphysema compared to CT (p < 0.05). Image quality of central airways and depiction of bronchi were significantly better in CODE than in VIBE (p < 0.001 and p = 0.005). In contrast, the depiction of the vasculature was better for VIBE than CODE images (p = 0.003). The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were significant greater in VIBE than CODE except for SNRlung and SNRnodule (p < 0.05). CONCLUSIONS: Our study showed the potential of CODE and VIBE sequences in the evaluation of localized thoracic abnormalities including solid pulmonary nodules.


Subject(s)
Lung Neoplasms , Magnetic Resonance Imaging , Tomography, X-Ray Computed , Humans , Female , Male , Middle Aged , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/pathology , Aged , Tomography, X-Ray Computed/methods , Magnetic Resonance Imaging/methods , Imaging, Three-Dimensional/methods , Adult , Lung/diagnostic imaging , Lung/pathology , Retrospective Studies , Breath Holding
3.
Otol Neurotol ; 45(5): 521-528, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38728554

ABSTRACT

PURPOSE: To evaluate a system for otomicrosurgery based on 4K three-dimensional (3D) exoscope technology and apply it to cochlear implantation. METHODS: An open stereoscopic vision-based surgical system, which differs from traditional surgical microscopes, was created by utilizing 4K stereo imaging technology and combining it with low-latency 4K ultra-high-definition 3D display. The system underwent evaluation based on 57 cochlear implantation operations, three designed microscopic manipulations, and a questionnaire survey. RESULTS: The surgical images displayed by the 4K-3D exoscope system (4K-3D-ES) are stereoscopic, clear, and smooth. The use of 4K-3D-ES in cochlear implantation is not inferior to traditional microscopes in terms of intraoperative bleeding and surgical complications, and the surgical duration is not slower or may even be faster than when using traditional microscopes. The results of micromanipulation experiments conducted on 16 students also confirmed this and demonstrated that 4K-3D-ES can be easily adapted. Furthermore, additional advantages of 4K-3D-ES were gathered. Significantly enlarged and high-definition stereoscopic images contribute to the visualization of finer anatomical microstructures such as chordae tympani, ensuring safer surgery. Users feel more comfortable in their necks, shoulders, waists, and backs. Real-time shared stereoscopic view for multiple people, convenient for collaboration and teaching. The ear endoscope and 4K-3D-ES enable seamless switching on the same screen. High-definition 3D images and videos can be saved with just one click, making future publication and communication convenient. CONCLUSION: The feasibility and safety of 4K-3D-ES for cochlear implantation surgery have been demonstrated. The 4K-3D-ES also offers numerous unique advantages and holds clinical application and promotional value.


Subject(s)
Cochlear Implantation , Humans , Cochlear Implantation/methods , Cochlear Implantation/instrumentation , Male , Female , Child , Imaging, Three-Dimensional/methods , Adult , Middle Aged , Microsurgery/methods , Microsurgery/instrumentation , Child, Preschool , Adolescent , Young Adult , Aged , Infant
4.
Sci Rep ; 14(1): 10760, 2024 05 10.
Article in English | MEDLINE | ID: mdl-38729983

ABSTRACT

Measurement of auricle parameters for planning and post-operative evaluation presents substantial challenges due to the complex 3D structure of the human auricle. Traditional measurement methods rely on manual techniques, resulting in limited precision. This study introduces a novel automated surface-based three-dimensional measurement method for quantifying human auricle parameters. The method was applied to virtual auricles reconstructed from Computed Tomography (CT) scans of a cadaver head and subsequent measurement of important clinically relevant aesthetical auricular parameters (length, width, protrusion, position, auriculocephalic angle, and inclination angle). Reference measurements were done manually (using a caliper and using a 3D landmarking method) and measurement precision was compared to the automated method. The CT scans were performed using both a contemporary high-end and a low-end CT scanner. Scans were conducted at a standard scanning dose, and at half the dose. The automatic method demonstrated significantly higher precision in measuring auricle parameters compared to manual methods. Compared to traditional manual measurements, precision improved for auricle length (9×), width (5×), protrusion (5×), Auriculocephalic Angle (5-54×) and posteroanterior position (23×). Concerning parameters without comparison with a manual method, the precision level of supero-inferior position was 0.489 mm; and the precisions of the inclination angle measurements were 1.365 mm and 0.237 mm for the two automated methods investigated. Improved precision of measuring auricle parameters was associated with using the high-end scanner. A higher dose was only associated with a higher precision for the left auricle length. The findings of this study emphasize the advantage of automated surface-based auricle measurements, showcasing improved precision compared to traditional methods. This novel algorithm has the potential to enhance auricle reconstruction and other applications in plastic surgery, offering a promising avenue for future research and clinical application.


Subject(s)
Algorithms , Ear Auricle , Imaging, Three-Dimensional , Tomography, X-Ray Computed , Humans , Ear Auricle/diagnostic imaging , Ear Auricle/anatomy & histology , Tomography, X-Ray Computed/methods , Imaging, Three-Dimensional/methods , Cadaver , Male
5.
BMC Oral Health ; 24(1): 549, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38730377

ABSTRACT

BACKGROUND: With the development and utilization of three-dimensional (3D) intraoral scanning (IOS) technology, the morphological characteristics of teeth were quantitatively assessed. In this research, we aimed to explore the prevalence of dental caries in relation to each measurable morphological indicator of the tooth body via 3D intraoral scanning techniques. METHODS: A hospital-based single-centre study was conducted at our hospital from Dec. 2021 to Apr. 2023. A total of 53 patients were involved in the study, providing complete morphological data for 79 teeth. Each patient completed an oral hygiene routine questionnaire and underwent examination by an experienced dentist to evaluate caries conditions before undergoing 3D intraoral scanning to obtain a digital dental model. Geomagic Studio 2014 was used to extract oral morphological data from the models. The acquired data were entered, cleaned and edited using Excel 2016 and subsequently exported to SPSS version 25.0 for analysis. Chi-square analysis and logistic regression analyses were employed to test the associations. RESULTS: Among the participants, 33 (61.1%) were female, with a mean age of 26.52 ± 10.83 years. Significant associations were found between dental caries and the vertical distance between the distal tip and the gum (OR 14.02; 95% CI 1.80-109.07; P = 0.012), the distal lateral horizontal distance of occlusion (OR 0.40; 95% CI 0.18-0.90; P = 0.026), and the mesial horizontal distance of occlusion (OR 2.20; 95% CI 1.12-4.31; P = 0.021). The Hosmer-Lemeshow test indicated a P value of 0.33. CONCLUSIONS: The vertical distance between the distal tip and the gum, the distal lateral horizontal distance of the occlusion and the mesial horizontal distance of the occlusion were the influencing factors for dental caries (identified as independent risk factors). We hypothesize that these factors may be associated with the physiological curvature of teeth and the role of chewing grooves in plaque formation over time. However, further studies involving larger population samples and more detailed age stratification are still needed.


Subject(s)
Dental Caries , Imaging, Three-Dimensional , Tooth Crown , Humans , Dental Caries/diagnostic imaging , Dental Caries/pathology , Female , Male , Imaging, Three-Dimensional/methods , Adult , Tooth Crown/pathology , Tooth Crown/diagnostic imaging , Adolescent
6.
Int J Mol Sci ; 25(9)2024 Apr 28.
Article in English | MEDLINE | ID: mdl-38732037

ABSTRACT

Mitochondria are the energy factories of a cell, and depending on the metabolic requirements, the mitochondrial morphology, quantity, and membrane potential in a cell change. These changes are frequently assessed using commercially available probes. In this study, we tested the suitability of three commercially available probes-namely 5',6,6'-tetrachloro-1,1',3,3'-tetraethylbenzimidazolo-carbocyanine iodide (JC-1), MitoTracker Red CMX Rox (CMXRos), and tetramethylrhodamine methyl ester (TMRM)-for assessing the mitochondrial quantity, morphology, and membrane potential in living human mesoangioblasts in 3D with confocal laser scanning microscope (CLSM) and scanning disk confocal microscope (SDCM). Using CLSM, JC-1, and CMXRos-but not TMRM-uncovered considerable background and variation. Using SDCM, the background signal only remained apparent for the JC-1 monomer. Repetitive imaging of CMXRos and JC-1-but not TMRM-demonstrated a 1.5-2-fold variation in signal intensity between cells using CLSM. The use of SDCM drastically reduced this variation. The slope of the relative signal intensity upon repetitive imaging using CLSM was lowest for TMRM (-0.03) and highest for CMXRos (0.16). Upon repetitive imaging using SDCM, the slope varied from 0 (CMXRos) to a maximum of -0.27 (JC-1 C1). Conclusively, our data show that TMRM staining outperformed JC-1 and CMXRos dyes in a (repetitive) 3D analysis of the entire mitochondrial quantity, morphology, and membrane potential in living cells.


Subject(s)
Imaging, Three-Dimensional , Microscopy, Confocal , Mitochondria , Humans , Mitochondria/metabolism , Microscopy, Confocal/methods , Imaging, Three-Dimensional/methods , Fluorescent Dyes/chemistry , Membrane Potential, Mitochondrial , Carbocyanines/chemistry , Rhodamines/chemistry
7.
BMC Oral Health ; 24(1): 561, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38745284

ABSTRACT

BACKGROUND: Prefabricated myofunctional appliance can guide tooth eruption, improve dentition alignment, correct myofunctional disorders and harmful oral habits. However, its application to skeletal discrepancy may result in unsatisfactory tooth inclination. This study aimed to construct a novel appliance with overjet design to avoid this side effect and investigated its shape and mechanical changes under occlusion using three-dimensional finite element method. METHODS: We established three samples of prefabricated myofunctional appliances. The first one was edge to edge without overjet, and the outer shield of both jaws were flattened. The second one was 3 mm overjet with stepped the outer shield. The last one was 3 mm overjet, and the outer shield of both jaws were flatted, which meant the front wall of lower jaw was strengthened with bumper, termed as lower bumper. A complete dentition model was applied to the study. 150 N occlusal force was applied to each type of appliance and the deformation displacement and the changes in stress was recorded. RESULTS: The deformation was significant in the incisors regions, especially in the vertical and lateral dimensions. The maximum displacements of 3 mm overjet with step shield group were 7.08 mm (vertical), 3.99 mm (lateral), and 2.90 mm (sagittal), while it decreased to 3.92 mm(vertical), 1.94 mm (lateral), and 1.55 mm (sagittal) in overjet with bumper group. Moreover, the upper molar regions exhibited higher vertical and sagittal displacement in 3 mm overjet with step shield group, which were 3.03 mm (vertical) and 1.99 mm (sagittal), and the bumper design could decrease the maximum displacement to 1.72 mm (vertical) and 0.72 mm (sagittal). In addition, the Von Mises stress of appliances was analyzed, and results indicated that 3 mm overjet with step shield generated higher stress than other groups, with the maximum Von Mises stress was 0.9387 MP, which were 0.5858 and 0.5657 MP in edge to edge group and 3 mm overjet with lower bumper group, respectively. CONCLUSION: The prefabricated myofunctional appliances may cause deformation during occlusion. Compared to step shield group, the application of lower bumper exhibited better resistance to occlusal force.


Subject(s)
Finite Element Analysis , Orthodontic Appliance Design , Humans , Myofunctional Therapy/instrumentation , Myofunctional Therapy/methods , Bite Force , Imaging, Three-Dimensional/methods , Overbite/therapy , Stress, Mechanical , Mandible , Incisor , Biomechanical Phenomena
8.
Cell ; 187(10): 2502-2520.e17, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38729110

ABSTRACT

Human tissue, which is inherently three-dimensional (3D), is traditionally examined through standard-of-care histopathology as limited two-dimensional (2D) cross-sections that can insufficiently represent the tissue due to sampling bias. To holistically characterize histomorphology, 3D imaging modalities have been developed, but clinical translation is hampered by complex manual evaluation and lack of computational platforms to distill clinical insights from large, high-resolution datasets. We present TriPath, a deep-learning platform for processing tissue volumes and efficiently predicting clinical outcomes based on 3D morphological features. Recurrence risk-stratification models were trained on prostate cancer specimens imaged with open-top light-sheet microscopy or microcomputed tomography. By comprehensively capturing 3D morphologies, 3D volume-based prognostication achieves superior performance to traditional 2D slice-based approaches, including clinical/histopathological baselines from six certified genitourinary pathologists. Incorporating greater tissue volume improves prognostic performance and mitigates risk prediction variability from sampling bias, further emphasizing the value of capturing larger extents of heterogeneous morphology.


Subject(s)
Imaging, Three-Dimensional , Prostatic Neoplasms , Humans , Imaging, Three-Dimensional/methods , Prostatic Neoplasms/pathology , Prostatic Neoplasms/diagnostic imaging , Male , Prognosis , Deep Learning , X-Ray Microtomography/methods , Supervised Machine Learning
10.
J Biomed Opt ; 29(6): 066002, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38745984

ABSTRACT

Significance: Optical coherence tomography (OCT) has emerged as the standard of care for diagnosing and monitoring the treatment of various ocular disorders due to its noninvasive nature and in vivo volumetric acquisition capability. Despite its widespread applications in ophthalmology, motion artifacts remain a challenge in OCT imaging, adversely impacting image quality. While several multivolume registration algorithms have been developed to address this issue, they are often designed to cater to one specific OCT system or acquisition protocol. Aim: We aim to generate an OCT volume free of motion artifacts using a system-agnostic registration algorithm that is independent of system specifications or protocol. Approach: We developed a B-scan registration algorithm that removes motion and corrects for both translational eye movements and rotational angle differences between volumes. Tests were carried out on various datasets obtained from two different types of custom-built OCT systems and one commercially available system to determine the reliability of the proposed algorithm. Additionally, different system specifications were used, with variations in axial resolution, lateral resolution, signal-to-noise ratio, and real-time motion tracking. The accuracy of this method has further been evaluated through mean squared error (MSE) and multiscale structural similarity index measure (MS-SSIM). Results: The results demonstrate improvements in the overall contrast of the images, facilitating detailed visualization of retinal vasculatures in both superficial and deep vasculature plexus. Finer features of the inner and outer retina, such as photoreceptors and other pathology-specific features, are discernible after multivolume registration and averaging. Quantitative analyses affirm that increasing the number of averaged registered volumes will decrease MSE and increase MS-SSIM as compared to the reference volume. Conclusions: The multivolume registered data obtained from this algorithm offers significantly improved visualization of the retinal microvascular network as well as retinal morphological features. Furthermore, we have validated that the versatility of our methodology extends beyond specific OCT modalities, thereby enhancing the clinical utility of OCT for the diagnosis and monitoring of ocular pathologies.


Subject(s)
Algorithms , Imaging, Three-Dimensional , Retina , Tomography, Optical Coherence , Tomography, Optical Coherence/methods , Retina/diagnostic imaging , Humans , Imaging, Three-Dimensional/methods , Artifacts , Reproducibility of Results , Signal-To-Noise Ratio
11.
Clin Oral Investig ; 28(6): 311, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38743171

ABSTRACT

OBJECTIVE: This study used image-based finite element analysis (FEA) to assess the biomechanical changes in mandibular first molars resulting from alterations in the position of the root canal isthmus. METHODS: A healthy mandibular first molar, characterized by two intact root canals and a cavity-free surface, was selected as the subject. A three-dimensional model for the molar was established using scanned images of the patient's mandibular teeth. Subsequently, four distinct finite element models were created, each representing varied root canal morphologies: non-isthmus (Group A), isthmus located at the upper 1/3 of the root (Group B), middle 1/3 of the root (Group C), and lower 1/3 of the root (Group D). A static load of 200 N was applied along the tooth's longitudinal axis on the occlusal surface to simulate regular chewing forces. The biomechanical assessment was conducted regarding the mechanical stress profile within the root dentin. The equivalent stress (Von Mises stress) was used to assess the biomechanical features of mandibular teeth under mechanical loading. RESULTS: In Group A (without an isthmus), the maximum stress was 22.2 MPa, while experimental groups with an isthmus exhibited higher stresses, reaching up to 29.4 MPa. All maximum stresses were concentrated near the apical foramen. The presence of the isthmus modified the stress distribution in the dentin wall of the tooth canal. Notably, dentin stresses at specific locations demonstrated differences: at 8 mm from the root tip, Group B: 13.6 MPa vs. Group A: 11.4 MPa; at 3 mm from the root tip, Group C: 14.2 MPa vs. Group A: 4.5 MPa; at 1 mm from the root tip, Group D: 25.1 MPa vs. Group A: 10.3 MPa. The maximum stress in the root canal dentin within the isthmus region was located either at the top or bottom of the isthmus. CONCLUSION: A root canal isthmus modifies the stress profile within the dentin. The maximum stress occurs near the apical foramen and significantly increases when the isthmus is located closer to the apical foramina.


Subject(s)
Dental Pulp Cavity , Dental Stress Analysis , Finite Element Analysis , Mandible , Molar , Humans , Biomechanical Phenomena , Dental Pulp Cavity/anatomy & histology , Dental Stress Analysis/methods , Imaging, Three-Dimensional/methods , Stress, Mechanical
12.
Eur Radiol Exp ; 8(1): 58, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38735899

ABSTRACT

BACKGROUND: Chondrosarcomas are rare malignant bone tumors diagnosed by analyzing radiological images and histology of tissue biopsies and evaluating features such as matrix calcification, cortical destruction, trabecular penetration, and tumor cell entrapment. METHODS: We retrospectively analyzed 16 cartilaginous tumor tissue samples from three patients (51-, 54-, and 70-year-old) diagnosed with a dedifferentiated chondrosarcoma at the femur, a moderately differentiated chondrosarcoma in the pelvis, and a predominantly moderately differentiated chondrosarcoma at the scapula, respectively. We combined a hematein-based x-ray staining with high-resolution three-dimensional (3D) microscopic x-ray computed tomography (micro-CT) for nondestructive 3D tumor assessment and tumor margin evaluation. RESULTS: We detected trabecular entrapment on 3D micro-CT images and followed bone destruction throughout the volume. In addition to staining cell nuclei, hematein-based staining also improved the visualization of the tumor matrix, allowing for the distinction between the tumor and the bone marrow cavity. The hematein-based staining did not interfere with further conventional histology. There was a 5.97 ± 7.17% difference between the relative tumor area measured using micro-CT and histopathology (p = 0.806) (Pearson correlation coefficient r = 0.92, p = 0.009). Signal intensity in the tumor matrix (4.85 ± 2.94) was significantly higher in the stained samples compared to the unstained counterparts (1.92 ± 0.11, p = 0.002). CONCLUSIONS: Using nondestructive 3D micro-CT, the simultaneous visualization of radiological and histopathological features is feasible. RELEVANCE STATEMENT: 3D micro-CT data supports modern radiological and histopathological investigations of human bone tumor specimens. It has the potential for being an integrative part of clinical preoperative diagnostics. KEY POINTS: • Matrix calcifications are a relevant diagnostic feature of bone tumors. • Micro-CT detects all clinically diagnostic relevant features of x-ray-stained chondrosarcoma. • Micro-CT has the potential to be an integrative part of clinical diagnostics.


Subject(s)
Bone Neoplasms , Chondrosarcoma , Feasibility Studies , Imaging, Three-Dimensional , X-Ray Microtomography , Humans , Chondrosarcoma/diagnostic imaging , Chondrosarcoma/pathology , X-Ray Microtomography/methods , Aged , Bone Neoplasms/diagnostic imaging , Bone Neoplasms/pathology , Middle Aged , Retrospective Studies , Imaging, Three-Dimensional/methods , Male , Female , Staining and Labeling/methods
13.
PLoS One ; 19(5): e0299925, 2024.
Article in English | MEDLINE | ID: mdl-38739571

ABSTRACT

The quest for higher spatial and/or temporal resolution in functional MRI (fMRI) while preserving a sufficient temporal signal-to-noise ratio (tSNR) has generated a tremendous amount of methodological contributions in the last decade ranging from Cartesian vs. non-Cartesian readouts, 2D vs. 3D acquisition strategies, parallel imaging and/or compressed sensing (CS) accelerations and simultaneous multi-slice acquisitions to cite a few. In this paper, we investigate the use of a finely tuned version of 3D-SPARKLING. This is a non-Cartesian CS-based acquisition technique for high spatial resolution whole-brain fMRI. We compare it to state-of-the-art Cartesian 3D-EPI during both a retinotopic mapping paradigm and resting-state acquisitions at 1mm3 (isotropic spatial resolution). This study involves six healthy volunteers and both acquisition sequences were run on each individual in a randomly-balanced order across subjects. The performances of both acquisition techniques are compared to each other in regards to tSNR, sensitivity to the BOLD effect and spatial specificity. Our findings reveal that 3D-SPARKLING has a higher tSNR than 3D-EPI, an improved sensitivity to detect the BOLD contrast in the gray matter, and an improved spatial specificity. Compared to 3D-EPI, 3D-SPARKLING yields, on average, 7% more activated voxels in the gray matter relative to the total number of activated voxels.


Subject(s)
Brain Mapping , Brain , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Signal-To-Noise Ratio , Humans , Adult , Magnetic Resonance Imaging/methods , Male , Brain Mapping/methods , Imaging, Three-Dimensional/methods , Brain/diagnostic imaging , Brain/physiology , Female , Echo-Planar Imaging/methods , Young Adult
14.
Sci Rep ; 14(1): 10875, 2024 05 13.
Article in English | MEDLINE | ID: mdl-38740845

ABSTRACT

Three-dimensional information is essential for a proper understanding of the healing potential of the menisci and their overall role in the knee joint. However, to date, the study of meniscal vascularity has relied primarily on two-dimensional imaging techniques. Here we present a method to elucidate the intricate 3D meniscal vascular network, revealing its spatial arrangement, connectivity and density. A polymerizing contrast agent was injected into the femoral artery of human cadaver legs, and the meniscal microvasculature was examined using micro-computed tomography at different levels of detail and resolution. The 3D vascular network was quantitatively assessed in a zone-base analysis using parameters such as diameter, length, tortuosity, and branching patterns. The results of this study revealed distinct vascular patterns within the meniscus, with the highest vascular volume found in the outer perimeniscal zone. Variations in vascular parameters were found between the different circumferential and radial meniscal zones. Moreover, through state-of-the-art 3D visualization using micro-CT, this study highlighted the importance of spatial resolution in accurately characterizing the vascular network. These findings, both from this study and from future research using this technique, improve our understanding of microvascular distribution, which may lead to improved therapeutic strategies.


Subject(s)
Imaging, Three-Dimensional , Microvessels , X-Ray Microtomography , Humans , Imaging, Three-Dimensional/methods , Microvessels/diagnostic imaging , X-Ray Microtomography/methods , Menisci, Tibial/diagnostic imaging , Menisci, Tibial/blood supply , Meniscus/diagnostic imaging , Male , Cadaver , Female
15.
PLoS One ; 19(5): e0295774, 2024.
Article in English | MEDLINE | ID: mdl-38713694

ABSTRACT

BACKGROUND: Magnetically assisted capsule endoscopy (MACE) showed the feasibility for upper gastrointestinal examination. To further enhance the performance of conventional MACE, it is necessary to provide quality-improved and three-dimensional images. The aim of this clinical study was to determine the efficacy and safety of novel three-dimensional MACE (3D MACE) for upper gastrointestinal and small bowel examination at once. METHODS: This was a prospective, single-center, non-randomized, and sequential examination study (KCT0007114) at Dongguk University Ilsan Hospital. Adult patients who visited for upper endoscopy were included. The study protocol was conducted in two stages. First, upper gastrointestinal examination was performed using 3D MACE, and a continuous small bowel examination was performed by conventional method of capsule endoscopy. Two hours later, an upper endoscopy was performed for comparison with 3D MACE examination. The primary outcome was confirmation of major gastric structures (esophagogastric junction, cardia/fundus, body, angle, antrum, and pylorus). Secondary outcomes were confirmation of esophagus and duodenal bulb, accuracy for gastric lesions, completion of small bowel examination, 3D image reconstruction of gastric lesion, and safety. RESULTS: Fifty-five patients were finally enrolled. The examination time of 3D MACE was 14.84 ± 3.02 minutes and upper endoscopy was 5.22 ± 2.39 minutes. The confirmation rate of the six major gastric structures was 98.6% in 3D MACE and 100% in upper endoscopy. Gastric lesions were identified in 43 patients during 3D MACE, and 40 patients during upper endoscopy (Sensitivity 0.97). 3D reconstructed images were acquired for all lesions inspected by 3D MACE. The continuous small bowel examination by 3D MACE was completed in 94.5%. 3D MACE showed better overall satisfaction (3D MACE 9.55 ± 0.79 and upper endoscopy 7.75 ± 2.34, p<0.0001). There were no aspiration or significant adverse event or capsule retention in the 3D MACE examination. CONCLUSIONS: Novel 3D MACE system is more advanced diagnostic modality than the conventional MACE. And it is possible to perform serial upper gastrointestinal and small bowel examination as a non-invasive and one-step test. It would be also served as a bridge to pan-endoscopy.


Subject(s)
Capsule Endoscopy , Imaging, Three-Dimensional , Intestine, Small , Humans , Capsule Endoscopy/methods , Capsule Endoscopy/adverse effects , Male , Female , Intestine, Small/diagnostic imaging , Intestine, Small/pathology , Middle Aged , Imaging, Three-Dimensional/methods , Prospective Studies , Adult , Aged , Upper Gastrointestinal Tract/diagnostic imaging , Upper Gastrointestinal Tract/pathology
16.
Ups J Med Sci ; 1292024.
Article in English | MEDLINE | ID: mdl-38716075

ABSTRACT

Since various imaging modalities have been developed, cancer metastasis can be detected from an early stage. However, limitations still exist, especially in terms of spatial resolution. Tissue-clearing technology has emerged as a new imaging modality in cancer research, which has been developed and utilized for a long time mainly in neuroscience field. This method enables us to detect cancer metastatic foci with single-cell resolution at whole mouse body/organ level. On top of that, 3D images of cancer metastasis of whole mouse organs make it easy to understand their characteristics. Recently, further applications of tissue clearing methods were reported in combination with reporter systems, labeling, and machine learning. In this review, we would like to provide an overview of this technique and current applications in cancer research and discuss their potentials and limitations.


Subject(s)
Disease Progression , Imaging, Three-Dimensional , Neoplasm Metastasis , Neoplasms , Animals , Mice , Humans , Neoplasms/pathology , Neoplasms/diagnostic imaging , Imaging, Three-Dimensional/methods , Machine Learning
17.
PLoS One ; 19(5): e0302514, 2024.
Article in English | MEDLINE | ID: mdl-38718004

ABSTRACT

Expanding spatial presentation from two-dimensional profile transects to three-dimensional ocean mapping is key for a better understanding of ocean processes. Phytoplankton distributions can be highly patchy and the accurate identification of these patches with the context, variability, and uncertainty of measurements on relevant scales is difficult to achieve. Traditional sampling methods, such as plankton nets, water samplers and in-situ vertical sensors, provide a snapshot and often miss the fine-scale horizontal and temporal variability. Here, we show how two autonomous underwater vehicles measured, adapted to, and reported real-time chlorophyll a measurements, giving insights into the spatiotemporal distribution of phytoplankton biomass and patchiness. To gain the maximum available information within their sensing scope, the vehicles moved in an adaptive fashion, looking for the regions of the highest predicted chlorophyll a concentration, the greatest uncertainty, and the least possibility of collision with other underwater vehicles and ships. The vehicles collaborated by exchanging data with each other and operators via satellite, using a common segmentation of the area to maximize information exchange over the limited bandwidth of the satellite. Importantly, the use of multiple autonomous underwater vehicles reporting real-time data combined with targeted sampling can provide better match with sampling towards understanding of plankton patchiness and ocean processes.


Subject(s)
Chlorophyll A , Oceans and Seas , Phytoplankton , Chlorophyll A/analysis , Environmental Monitoring/methods , Chlorophyll/analysis , Biomass , Imaging, Three-Dimensional/methods
18.
Science ; 384(6696): eadm7168, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38723062

ABSTRACT

Despite a half-century of advancements, global magnetic resonance imaging (MRI) accessibility remains limited and uneven, hindering its full potential in health care. Initially, MRI development focused on low fields around 0.05 Tesla, but progress halted after the introduction of the 1.5 Tesla whole-body superconducting scanner in 1983. Using a permanent 0.05 Tesla magnet and deep learning for electromagnetic interference elimination, we developed a whole-body scanner that operates using a standard wall power outlet and without radiofrequency and magnetic shielding. We demonstrated its wide-ranging applicability for imaging various anatomical structures. Furthermore, we developed three-dimensional deep learning reconstruction to boost image quality by harnessing extensive high-field MRI data. These advances pave the way for affordable deep learning-powered ultra-low-field MRI scanners, addressing unmet clinical needs in diverse health care settings worldwide.


Subject(s)
Deep Learning , Magnetic Resonance Imaging , Whole Body Imaging , Magnetic Resonance Imaging/methods , Whole Body Imaging/methods , Humans , Imaging, Three-Dimensional/methods
19.
IEEE Trans Image Process ; 33: 3285-3300, 2024.
Article in English | MEDLINE | ID: mdl-38709601

ABSTRACT

We live in a 3D world where people interact with each other in the environment. Learning 3D posed humans therefore requires us to perceive and interpret these interactions. This paper proposes LEAPSE, a novel method that learns salient instance affordances for estimating a posed body from a single RGB image in a non-parametric manner. Existing methods mostly ignore the environment and estimate the human body independently from the surroundings. We capture the influences of non-contact and contact instances on a posed body as an adequate representation of the "environment affordances". The proposed method learns the global relationships between 3D joints, body mesh vertices, and salient instances as environment affordances on the human body. LEAPSE achieved state-of-the-art results on the 3DPW dataset with many affordance instances, and also demonstrated excellent performance on Human3.6M dataset. We further demonstrate the benefit of our method by showing that the performance of existing weak models can be significantly improved when combined with our environment affordance module.


Subject(s)
Algorithms , Imaging, Three-Dimensional , Posture , Humans , Imaging, Three-Dimensional/methods , Posture/physiology , Databases, Factual , Machine Learning
20.
Sci Rep ; 14(1): 10136, 2024 05 02.
Article in English | MEDLINE | ID: mdl-38698049

ABSTRACT

Exocrine and endocrine pancreas are interconnected anatomically and functionally, with vasculature facilitating bidirectional communication. Our understanding of this network remains limited, largely due to two-dimensional histology and missing combination with three-dimensional imaging. In this study, a multiscale 3D-imaging process was used to analyze a porcine pancreas. Clinical computed tomography, digital volume tomography, micro-computed tomography and Synchrotron-based propagation-based imaging were applied consecutively. Fields of view correlated inversely with attainable resolution from a whole organism level down to capillary structures with a voxel edge length of 2.0 µm. Segmented vascular networks from 3D-imaging data were correlated with tissue sections stained by immunohistochemistry and revealed highly vascularized regions to be intra-islet capillaries of islets of Langerhans. Generated 3D-datasets allowed for three-dimensional qualitative and quantitative organ and vessel structure analysis. Beyond this study, the method shows potential for application across a wide range of patho-morphology analyses and might possibly provide microstructural blueprints for biotissue engineering.


Subject(s)
Imaging, Three-Dimensional , Multimodal Imaging , Pancreas , Animals , Imaging, Three-Dimensional/methods , Pancreas/diagnostic imaging , Pancreas/blood supply , Swine , Multimodal Imaging/methods , X-Ray Microtomography/methods , Islets of Langerhans/diagnostic imaging , Islets of Langerhans/blood supply , Tomography, X-Ray Computed/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...